Search all Powell websites:
|
|
UniPro™ R Pneumatic Emergency Valve Closure System
Avoid production slowdowns, operator injury, or lengthy and expensive environmental cleanups by stopping dangerous chemical leaks with the UniPro™ R Valve Closure System. The only reversible emergency valve closure technology designed for 20-ton bullet tanks to 90-ton railcars, this patent-pending system prevents reportable releases of pressurized hazardous gases at the source. Plus, the UniPro™ R system is easily "reversible" - helping reduce operator effort and potential injuries. Improve your Risk Management Planning (RMP) scenarios with a pneumatic-powered system that not only promises easy installation and low maintenance, but also superior performance and reliability.

U.S. Patent 6,871,834
The UniPro™ R is designed to stand alone as a complete system, or to integrate and interface with existing unloading components. The manual activation lever allows the operator to open and close the valve on demand. The included air supply hose has a safety swing coupling to ensure a secure connection between actuator and gas supply.
LOW MAINTENANCE
Robust motor requires no lubrication, and is completely encased by a steel cover for protection and years of reliable service.
*Designed in accordance with
The Chlorine Institute’s guidelines for valve closure systems.
|
|
|
|
REVERSIBLE
Easily opens tightly closed valves with just a pull on the lever. No need for T-bars and spanners. Pushing the lever in the opposite direction closes the valve. Reversible feature requires an additional air line (90 psig) and does not interfere with emergency operation mode. Designed for high-torque valves only. |
PNEUMATIC
Ideal for applications where air or nitrogen are readily available. Requires 90 psig to operate. Fail-closed design operates even if AC power or air pressure is lost.
VERSATILE
Designed to operate high-torque, plug-type angle valves on railcars and tank trucks with dome sizes between 24 and 42 inches in diameter. For use on containers of chlorine*, sulfur dioxide, anhydrous ammonia, liquid hydrogen chloride, and other pressurized hazardous gases.
|
|
POWERFUL
Automatically responds to any alarm input, closing valves with 120 lb-ft of torque in less than 10 seconds.
EASY TO INSTALL
Easily mounts to the dome wall in seconds, without tools. Can be quickly removed from the valve handle without detaching from the dome wall to facilitate manual valve operation. Weighs only 30 pounds. |

|
|
The UniPro™ R Pneumatic Valve Closure System has been engineered, designed, and field-tested to ensure reliable performance while reducing installation time, maintenance, and material cost.
That’s Reliable Engineering. |
|
Designed for Durability
The actuator is constructed of aircraft-quality aluminum and high-grade carbon and stainless steels for maximum service life. The housing is sealed to prevent intrusion from dirt and water in outdoor applications, while a two-step polyurethane coating provides corrosion protection.
 |
Maximum Control
The UniPro™ Control Panel automatically activates the actuator to close the valve in the event of a gas leak, car movement, fire alarm, seismic event, security breach, process shutdown, or other monitored condition. You can also manually activate the system by depressing the emergency stop button on the panel. |
 |
Air Control Unit
The air control unit supplies the proper amount of clean pressurized air to the system. Available in two sizes to operate up to six UniPro™ actuators simultaneously.
UniPro™ System Components |
Versatility
The UniPro™ name represents a whole family of pneumatic actuators for railcar and tanker applications, including the standard, reversible and low-torque models, all designed for plug-type valves, plus a quarter-turn model specifically designed for ball-type valves. The control panel, air control unit, and all optional system components work with any of our pneumatic actuators.
UL - CUL Approved
Powell Valve Closure System control panels (UniPro™, MaxPro™ RA & E-Pro®) are listed by Underwriters Laboratory to UL 508A for Enclosed Industrial Control Panels. Panels are listed by Underwriters Laboratory bearing the UL & CUL mark for use in the United States and Canada markets. In applications where a CSA listed control panel in Canada is required, please contact Powell engineering for further information.
|
|
|
|
|
|
©Powell Fabrication & Manufacturing, Inc. |
|
|
|
|
|